Old Cast Iron Dampers: Fix or Replace

Have an Older Chimney?

By sending, you agree Delmar Chimney Care may contact you by call, automated text or email about your request. Consent isn't required to buy. Msg & data rates may apply; reply STOP to opt out. Privacy Policy

Two brick chimneys on a clay tile roof

A part that was built to be forgotten

In an older fireplace the damper is a hinged iron plate sitting in the throat, just above the firebox. On a house from the 1930s through the 1960s it was set in place while the chimney was laid, and the brick went up around it. Nobody expected it to come out again. That is the whole difficulty when it fails.

In Buena Park and the cities around it, most of the dampers we see are cast iron or stamped steel, worked by a handle or a rotary knob at the front of the firebox. After sixty or more years of heat, soot and rain falling down an uncovered flue, they fail in three ways.

The three ways an old damper fails

  • Rusted shut. The plate will not open, so the fireplace cannot be used. Sometimes the hinge has seized; sometimes rust has grown between plate and frame.
  • Rusted open, or gone. The plate has dropped or broken off. The house loses heat up the chimney all winter and takes in warm air all summer, and birds and rain have an easy way in.
  • Warped. The plate still moves but no longer meets the frame. The fire draws fine, but the seal is gone.

A fourth case is a damper that works but is in the way. When a liner is going in, a throat damper usually blocks the tube.

What can be done with it

There are three paths, and the right one depends on what the camera and a hand on the handle tell us.

1. Free and adjust. A seized hinge can often be cleaned, freed and set to close square. It is the least costly path, and it keeps the original part. 2. Replace the plate. On some designs the plate lifts out of its frame and a new one can be fitted. When the frame itself is cracked, this does not work. 3. Leave the throat open and seal the top. A damper mounted on top of the chimney closes against a gasket and is worked from a handle in the firebox. The old throat plate is removed or fixed open.

Cutting the old frame out of the brick and setting a new throat damper is possible but rarely worth it on an older chimney, because it means breaking into masonry that is otherwise sound.

How it is priced

Damper work has no list price here. A rusted hinge that frees in twenty minutes and a cracked frame that leads to a top sealing unit are very different jobs, so the figure you get is written down once we have looked at the throat and the flue above it.

The fixed prices that tend to sit beside damper work:

  • A Level 1 look at the fireplace and damper, $175.
  • A sweep from $445 when the throat is too sooty to judge.
  • The camera visit at $415 when the damper failure hints at something higher up, such as rust from water coming down the flue.

An older house often needs a cap at the top as well. That one is quoted after we measure.

If your damper will not open, will not close or shows a gap you can see light through, ask for a damper visit and say which of those it is and whether the fireplace burns wood or gas.

Why the damper matters more on an older house

A newer house has a tight shell, so a leaking damper is one of the few gaps left. An older house has more gaps already, and the damper is often the largest of them. A warped plate in a 1950s living room can let a steady stream of warm air out on a winter evening. In summer the flow reverses, and the chimney brings in hot air and the smell of old soot.

Then there is gas. If a gas log set has been added to an older fireplace, the damper has to stay open whenever the burner runs, or carry a clamp that keeps it from closing. Plenty of older Buena Park houses have log sets fitted years ago above a damper that can still swing shut. We check that on every visit, because it matters more than anything else on this list.

Signs it is time to call

  • The fireplace smells of soot on hot days.
  • The handle turns but nothing seems to move.
  • There is a draft at the hearth with the damper shut.
  • Rust flakes or debris collect on the firebox floor.
  • You have a gas log set and are not sure the damper is fixed open.

Pairing damper work with other repairs

On older chimneys damper work is seldom alone. A rusted plate is often the sign of water coming down the flue, which points to a missing cap, a failed crown or both. If we are on the roof anyway, those are checked and priced on the same visit. The damper repair page and the cap page give more detail on each, and the fireplace repair page covers the firebox below.